YTD5A Table-type Low Speed Centrifuge
Parameters
Model | TD5A | TD5Z |
Max Speed | 5500r/min | 5000r/min |
Max RCF | 5640×g | 4660×g |
Max Capacity | 2000ml | 800ml |
Speed Accuracy | ±20r/min | ±20r/min |
Time Range | 0-999min/sec | 0-999min/sec |
Power Supply | AC 220V 50Hz 15A | AC 220V 50Hz 10A |
Noise | ≤60dB | ≤60dB |
Dimension | 560×460×390mm | 560×460×390mm |
Weight | 58kg | 54kg |
YTD5A Rotor Parameters
Model | Number | Capacity | Max Speed(r/min) | Max RCF(×g) | Dimension of tube(mm) |
Swing Rotor | No.63 | 4×50/100ml | 5500 | 5640 | Φ38×124 |
No.69-1 | 4×500ml 12×50/32×15ml | 4000 | 3150 | Φ80×140 | |
No.69-2 | 72×5/7ml | 4000 | 3150 | Vacumm Blood Collection Tube | |
No.69-3 | 96×5/7ml | 4000 | 3150 | ||
No.70-1 | 4×250ml 4×50/4×15ml | 4000 | 2930 | Φ64×112 | |
No.70-2 | 48×5/7ml | 4000 | 2930 | Vacumm Blood Collection Tube | |
No.81-1 | 32×10/15ml | 4000 | 2960 | Φ16×114-118 | |
No.81-2 | 8×50/100ml | 4000 | 2960 | Φ28×105-115 | |
No.81-3 | 24×10/15ml | 4000 | 2960 | Φ16×114-118 | |
Microtiter Plate Rotor | No.43-1 | 2×2×96 holes | 4000 | 2540 | Microtiter Plate |
YTD5Z Rotor Parameters
Model | Number | Capacity | Max Speed(r/min) | Max RCF(×g) | Dimension of tube(mm) |
Swing Rotor | No.63 | 4×50/100ml | 5000 | 4660 | Φ38×124 |
No.70-2 | 48×5/7ml | 4000 | 2930 | Vacumm Blood Collection Tube | |
No.81-1 | 32×10/15ml | 4000 | 2960 | Φ16×114-118 | |
No.81-2 | 8×50/100ml | 4000 | 2960 | Φ28×105-115 | |
No.81-3 | 24×10/15ml | 4000 | 2960 | Φ16×114-118 | |
Microtiter Plate Rotor | No.43-1 | 2×2×96 holes | 4000 | 2540 | Microtiter Plate Rotor |
Features
1、Microprocessor control, operated by touch panel, visual digital display, operated data can be saved automatically, RCF value can be set directly for working, easy to use.
2、Brushless motor, imported super speed bearing from Europe, smooth running and maintenance free.
3、Steel body, stainless steel centrifugal chamber, multistage damping system, low noise and slight vibration, green.
4、With rotor identification, overspeed, door interlock, imbalance protections, the rotor can be high temperature & high pressure sterilization, ensure safety.
5、Special air current design, the temperature of centrifuge chamber is stable. can effectively protect the samples.
6、Adjustable acceleration and deceleration from grade 0 to 9 or directly set the time of Accel/Decel, 40 kinds of self-defining operating programs can be stored and recall, to achieve the best centrifugal result.
7、Hold-on and transient centrifuging, easy to diverse centrifugation.